FR MDF Manufacturer · Shuyang, China

Red Fire Retardant MDF for your interior project.

Choose red fire retardant MDF for furniture, wall panels and interior fit-outs. Our Shuyang factory supplies FR MDF boards and machined parts, with the finish and fire specification selected for your project.

Board type
Flame-retardant MDF core
For your production
Painting · facing · machining
Red Fire Rated MDF panels with matching faces and dense compact fibre edges

Technical specification

Fire Rated MDF Specifications

Fire Rated MDF, also called FR MDF, fire retardant MDF or red MDF board, uses a flame-retardant formulation. Choose the tested board and finish for the fire classification required by your interior project.

ThicknessMDF capability: 2–35 mm. The selected FR construction, actual thickness/density and finished faces follow the applicable classification and supporting-document coverage.
SizeCUZI MDF board formats: 1220 × 2440 mm; 2100 × 2800 mm; 1830 × 3660 mm; 1830 × 2440 mm; 2440 × 3660 mm; 1830 × 4200 mm.
DensityCUZI MDF density range: 2–4 mm: 800–810 kg/m³; 5–8 mm: 780–800 kg/m³; 9–11 mm: 760–780 kg/m³; 12–18 mm: 680–750 kg/m³; 19–35 mm: 650–680 kg/m³.
GlueThe bonding and additive system follows the selected fire-rated panel construction.
Formaldehyde gradeE0, E0.5 and E1 options. Tell us your destination and required test standard so we can help you choose the board and supporting reports.
SurfaceSanded and smooth; suitable for melamine pressing, painting and other downstream processes. Evaluate raw or faced options as complete constructions against the required fire classification, supporting test report or certificate and end-use scope.
Fire performanceFire performance follows the applicable standard or test method, reported classification, exact product construction, thickness and end-use scope. Confirm these details with the supporting documents for the quoted panel.
Thickness tolerance±0.1 mm nominal board thickness, with the measuring method agreed in the order. Finished-part tolerances follow the drawing.

Finish and processing

Fire classification, finish and installation

Product-specific fire classification

Send the required standard and classification. The report must cover the proposed board, thickness, facing and relevant installation conditions.

Paint, facing and CNC details

Specify coatings, decorative faces, cut-outs, grooves and fixing points together. Machining and finishing can affect the construction covered by a fire report.

Interior use and storage

Fire performance and moisture performance are separate requirements. Select the core for the room and store panels flat, dry and supported.

Selection guide

Fire reports and installed constructions

Read the Fire Rated MDF selection guide
Schematic bare FR MDF, complete faced panel and installed lining showing the product, face layers, reverse, backing, cavity and fixing information to match with fire documents
A diagram of the board, finished panel and wall lining. Use the fire report to choose the panel and installation for your project. View the construction drawing.

Begin with the fire requirement and the component you are buying

A hotel wall panel, retail fixture and furniture front can share the same smooth MDF appearance while following different project fire requirements. Bring us the named standard, target classification and intended use with your design. CUZI MDF manufactures and supplies FR MDF directly from our factory in Shuyang, Jiangsu, China. We help connect your proposed board, finish and processing with the applicable documents before the order is confirmed.

Fire rated MDF, fire retardant MDF and FR MDF are common purchasing terms for a flame-retardant MDF product. A request for fire resistant MDF needs the same specification detail: state whether the project concerns a material's reaction to fire or the timed performance of a complete wall, door or other assembly. That distinction helps your project team ask for the right information and lets our quotation describe the actual material supplied.

Begin with the fire requirement and the component you are buying
Project requirementWhat the document describesInformation to send with the inquiry
Reaction-to-fire classification under EN 13501-1The classified product and its end-use conditions, including the full reported class and relevant smoke/droplet designationRequired class, standard edition, intended wall/ceiling or other use, panel construction and installation details
Surface-burning requirement using ASTM E84Reported flame-spread and smoke-developed indices for the tested specimen and mountingRequired criteria, method edition, actual material/face, specimen construction, mounting and destination specification
Fire resistance of a wall, door or other assemblyPerformance of the tested assembly for the required duration and criteria under the specified methodAssembly design/reference, complete materials, framing, layers, joints, fixings and required test/classification documents

BSI's EN 13501-1 overview explains reaction-to-fire classification in relation to end use. ASTM's E84 scope describes surface-burning measurements and specimen support, while ASTM E119 concerns the fire performance of building elements during a specified exposure. Each method has its own criteria. Compare documents against the method your project names, with any equivalence accepted by the responsible project team.

Specify the bare board or the complete faced panel

Choose what you want to receive: bare FR MDF sheets, machined parts prepared for your finishing process, or a specified faced/coated panel. For an exposed finished surface, the MDF core, adhesive, decorative layer, reverse and edges form the construction to review. A board report and a finished-panel report can describe different products and end-use conditions. Keep the supply state clear in the quote, sample and document request.

Our input MDF capability spans 2–35 mm and the listed six sheet formats. The available FR thickness, density and format are selected with the applicable classification and document coverage. A general MDF production range describes factory capability; the order identifies the particular FR construction and its documented range. For a faced board, state core thickness and finished panel thickness separately, including the face, bond lines and reverse.

Specify the bare board or the complete faced panel
Specification itemBare or machined FR MDF orderFaced/coated panel order and document check
Product and classificationNamed FR board reference, required method and full reported class/resultIdentify the complete finished construction and matching class/result
Thickness and densityActual FR thickness, grade/density and the covered product rangeCore plus face, adhesive and reverse; actual finished thickness and covered range
Exposed faceSanded raw face and any machining shown in the drawingExact laminate, veneer, film or coating reference, thickness/build and exposed side
Reverse and edgesSupplied reverse, cut edges and planned next processReverse/balancing material, bonding, edge covering and openings
GeometryPart dimensions, grooves, hole/perforation pattern and remaining sectionsFinished geometry and changes to the tested construction or permitted scope
Mounting and backingProposed fixing method, support and intended end useBacking/substrate, cavity, joints, orientation and fixing conditions in the applicable documents
Order identificationProduct, drawing revision, sample, quantity and checksThe same references linked to the finish schedule, documents and packed parts

Ask for coverage of the exact combination. Where a classification permits a range or variation, its field of application establishes that range. A proposed change in thickness, facing, bonding, reverse, machining or mounting is checked against the applicable documentation and any further assessment the project requires. This gives your workshop a specification it can carry through finishing and installation.

What to look for in a fire declaration

A declaration, classification report and laboratory test report serve different purposes. The declaration identifies performance for a named product; the classification report records the class and field of application; supporting test reports describe the specimens, mounting, methods and results. Read them together when your project calls for that package, and retain any relevant installation instructions.

For a public reading example, MEDITE's CEDOP51 REV0 declaration dated 13 April 2026 identifies its own FR MDF and producer. Its declared scope shows why the product range and installation conditions belong beside the class.

What to look for in a fire declaration
Field in this external declarationInformation it givesPurchasing lesson
Product identityNamed MEDITE FR MDF, declaration CEDOP51 REV0 and identified manufacturerMatch the quoted product with its own document identity
Thickness bands4–6 mm and over 6–9 mmRead the declared range for the selected construction
Reaction to fireB-s2,d0 in both listed bandsKeep the full classification and its conditions together
Field of applicationHorizontal/vertical butt joints permitted; air gap up to 40 mm; substrate at least 9 mm, A2-s2,d0 or better and density at least 652.5 kg/m³, excluding paper-faced gypsum plasterboardCompare the complete backing, cavity and joint conditions with the proposed installation

This declaration is for the named MEDITE product. For a CUZI MDF order, ask us for the classification, supporting reports and installation details of the board we offer. Our FR MDF document guide expands the review sequence.

Connect finishing and machining with the installed construction

The smooth FR MDF face gives your design a practical starting point for coating and decorative facing. Specify the finish as precisely as the core. For paint, identify primer, topcoat, application/build and the faces and edges covered. For HPL MDF, Melamine MDF, veneer or film, identify the actual face material, thickness, adhesive and reverse. We review the proposed FR core and finish as the complete panel you will receive, with the available document coverage.

Routing, grooving and perforation alter the part's geometry and exposed surfaces. Show the profile section, depth, radius, hole pattern, solid borders, remaining material and edge treatment in the drawing. The CNC processing page helps prepare these details. An acoustic-panel request also identifies the backing/absorber, cavity, frame and installation; fire and acoustic documents each address their own complete system.

For wall panels, send an elevation and section showing which face is exposed, the supporting wall or substrate, any battens/frame, cavity, insulation or backing, fixing method and joints. Include panel orientation, sizes, holes, penetrations and edge conditions. A substrate's material, thickness, density or fire classification may be specified by the report. A cavity or fixing choice can also be part of its permitted use. These details help your project team compare the designed wall with the documented construction.

Treat a requested 30- or 60-minute wall as an assembly specification. Its board layers, framing, joints, fixings and other components follow the applicable assembly documents and design. We supply the agreed panel and processing scope; the responsible designer or project reviewer determines suitability of the full installation. For practical wall-layout and component planning, see MDF for Interior Wall Panels.

Include moisture exposure and emission requirements when choosing fire-rated MDF. Tell us the room conditions, finish, edges and destination so we can discuss a board that suits the complete brief.

Request a document package your project team can review

Send the requirement and the proposed construction with your document request. If the design is still developing, include the available plan/section and the items your project reviewer needs to resolve. We reply within 12 hours and help identify the panel options, relevant documents and specification details for the next decision. The quality page explains order checks and document matching.

Request a document package your project team can review
Requested itemInformation to connect with your quotationWhy it matters for the review
Product technical dataFR product/grade, actual thickness and density, faces, format and intended conditionsIdentifies the panel under consideration
Classification reportIssuer, report reference/date/revision, method, full class and field of applicationShows classification and permitted product/end-use scope
Supporting test reports where requiredTested product, specimen thickness/density, layer construction, mounting and reported resultsConnects the classification with the tested construction
Declaration/marking documents where applicableManufacturer/product identity, declared characteristics and intended useCompletes the document package requested for the destination/project
Installation or application detailsBacking, cavity, joints, support, fixings, orientation and permitted changesAllows comparison with the actual wall or component design
Order and batch identificationQuoted product, drawings, sample, document revisions, quantities and bundle/part labelsKeeps the approved specification connected with delivery and reorders

The request buttons on this page carry the FR product and page context into the inquiry. Share the target method/class and construction in your message; we can then respond with information for that proposed supply. Documents such as an SDS, management-system certificate or chain-of-custody record have their own purpose. The fire requirement is addressed by the applicable fire-performance and product documents.

For a changed design, send the revised face, profile, reverse, thickness or mounting information with the previous references. Agree the revised construction and document coverage before the next run. A current written record helps procurement, the workshop and the installation team work from the same specification.

Use samples and receiving checks for their intended purpose

A sample helps your workshop assess cutting, profile detail, finish adhesion, appearance and assembly fit. Fire performance comes from the applicable fire testing and classification for the construction. Request a representative sample with the actual board reference and finish or machining you want to assess; keep its identity and supplied condition with the drawing and document package.

All product samples can be requested free of charge and are generally in stock. You cover the courier cost, which can be credited against a formal order. We confirm the available sample, custom preparation where needed, dispatch, courier cost and estimated transit time for your delivery address. A representative finished part is useful when the appearance or fit depends on coating, facing, routing or installation details.

Agree receiving and pre-shipment checks for thickness, dimensions, face and edge condition, machining, identification and packing. Nominal MDF thickness tolerance is ±0.1 mm; the selected FR grade, measuring method and any finished-panel/component tolerances are recorded in the order. Check document references against the board/part identity and specified construction. Red MDF is a familiar purchasing name for the red-coloured fire-retardant grade. The colour helps identify boards during handling. Compare red MDF and green MDF to choose between fire and moisture requirements.

You can arrange a third-party inspection before shipment. Inspection checks the agreed supply and packing; fire testing follows its laboratory method and specimen requirements. Retain bundle/part IDs, quantities, current drawings, samples and document revisions at receipt. For repeat supply, use those references and confirm any change in grade, finish or component design with us.

Turn the agreed FR specification into a complete quotation

Start with the required fire method/class, intended use, board or component sizes, thickness, finish, quantities and destination. Add drawings, installation section and the document list. Tell us whether you want bare sheets, prepared parts or a complete faced/coated panel. Our team replies within 12 hours to help prepare a clear supply specification and quote for your project.

FOB China price: US$220–360/m³ for Fire Rated MDF. Your quote lists the selected board, quantity, finish, machining, documents and packing, plus delivery terms, production time, payment terms and validity. Compare the same board and included work when reviewing prices.

Normal MOQ is 1 × 20'GP per specification. Normal production lead time is 3–10 days after the specification, required documents and commercial terms are confirmed. MDF board production capacity is 500 m³ per day across the factory. The quote confirms the schedule for your selected FR construction, facing, machining and order; any additional project testing or custom sample preparation has its own agreed scope and timing.

MDF cover boards, clean separators where needed, face/edge protection, wrapping, supports, controlled strapping and clear labels are selected for your sheets or parts. Shipments use Lianyungang or Qingdao, with loading planned from actual sizes, density and packaging. Keep the FR product and part references with the packed order, so receiving, installation and the next purchase follow the agreed specification.

Applications

Applications of Fire Rated MDF

MDF for Interior Wall Panels

Order flat, veneered or grooved wall panels with the openings, trims and finish your interior needs. Our Shuyang factory supplies boards and machined modules to your elevation, keeping panel positions, adjoining finishes and installation packs coordinated.

Explore application

Boards and components

Fire Rated MDF photos and documents

Product documents for your order

Request the fire classification and supporting test report for the selected thickness and finish, including installation conditions. Emissions and any timed assembly fire-resistance requirement need their own documents.

Made in Shuyang, China

From our factory to your workshop

Work with Shuyang Cuzi MDF Co., Limited on board selection, machining, inspection and export packing. Our factory has a total daily production capacity of 500 m³ across its operations.

Delivery, returns and warranty

Delivery lead time
3–10 days
Shipment
By sea in containers
Delivery terms
FOB Qingdao / FOB Lianyungang, China
Warranty
180 days

Made to order. The usual minimum is 1 × 20'GP per specification; mixed sizes or finishes are quoted together. Delivery lead time starts after specifications and terms are confirmed; sea transit is scheduled separately.

Freight is calculated for your ports and cargo quantity. Returns and exchanges, including timing and costs, are agreed in the order.

Delivery and freight terms · Returns and 180-day warranty · Packing and loading information

FOB China price

US$220–360 per m³

Availability
Available to order
Request an exact quotation

Your quotation confirms the specification, quantity, packaging and final price.

Buyer FAQ

Your Fire Rated MDF questions, answered.

Is Fire Rated MDF fireproof?

FR MDF is a flame-retardant wood-based panel. Its formulation improves ignition and flame-spread behaviour under specified test conditions; prolonged or intense heat exposure can still cause charring and burning. The reported classification describes the tested product and conditions, and the finished construction follows the project specification.

What is the difference between reaction to fire and fire resistance?

Reaction to fire describes how a material contributes to a fire under a specified test, which can include flame spread, heat release, smoke or burning droplets. Fire resistance describes how an assembly, such as a wall or door, performs for a stated time. A 30- or 60-minute rating belongs to the tested assembly and its specified construction; select the FR board and assembly documents for the requirement your project sets.

Which fire classification can you supply?

Send the named standard or test method, target classification, destination and intended use. We confirm the available product and supporting documents for the proposed thickness, surface and construction. The quotation identifies the selected board; your project team can assess its documented performance against the requirement before order confirmation.

What should I check in the fire test documents?

Match the report issuer, reference and date, product identity, thickness, density or construction where specified, surface, test method and reported classification with the quoted panel. Read the applicable scope and any mounting, fixing, substrate or air-gap conditions. Your project team can then assess the proposed supply for its intended installation.

Does a fire classification apply to every thickness and finish?

The classification applies within the report's stated product range and field of application. Confirm that your chosen thickness, facing, coating, machining and installation are included. We help check the proposed panel against the available documents and identify any further information your project team needs.

What is red MDF board used for?

Red MDF board commonly means red fire retardant MDF. Choose it for interior wall panels, furniture and fit-outs with a fire requirement. The colour helps identify the board in the workshop; the selected FR grade and finished construction determine the applicable fire classification.

Can I request a free FR MDF sample?

Yes. All product samples can be requested free of charge and are generally in stock. You pay the courier cost, which can be credited against a formal order. Send the required board, thickness and delivery address; we confirm availability, dispatch timing, courier cost and estimated transit time. Custom sample preparation is confirmed with your request.

What installation information is needed for an FR wall-panel inquiry?

Send an elevation and section with the exposed face, panel dimensions, backing/substrate, cavity, frame or battens, insulation, joints, fixing method, orientation, openings and edges. Add the required fire method/class and any timed assembly requirement. Your project team compares these details with the applicable product and assembly documents.

Buyer guides

Practical guides for your MDF order.

MDF Documents for Interior Projects: A Buyer Checklist

Plan MDF for interior projects with a practical checklist of products, drawings, samples and test reports, from material selection to ordering.

Read guide

Red MDF vs Green MDF: Fire Retardant and Moisture Resistant Boards

Red MDF commonly identifies fire-retardant board, while green MDF commonly identifies moisture-resistant board. Choose by the job the panel needs to do, then match the grade, finish and dimensions.

Read guide

MDF Export Guide for International Buyers

An MDF export order works best when the product, commercial terms and shipment information agree from the start. Buy directly from our factory with a clear board or component specification, then confirm samples, packing, inspection and delivery milestones.

Read guide

Fire Rated MDF Documents: What Buyers Need

For a fire-rated MDF order, the useful answer is the classification that applies to the board or assembly you are buying. Match the product, thickness, facing and installation details to the applicable documents.

Read guide

Let's specify your FR MDF together.

Share the required fire classification, thickness, sizes, quantity and destination. We'll reply within 12 hours to help with product documents, a free sample and a written quote.